mmi203
1. Download SPLat Firmware
Download this firmware file for your controller. More information about the upgrade process can be found in the Knowledge Base.
************************ MMi203 Revision History ***********************************
*
* V3-0 25/09/2012 Initial release of MMi203 firmware, base on MMi202 V3-38 firmware. RTC module still needs testing.
*
* V3-10 17/10/2012 Setup RTC Calibration RTC module still needs testing.
*
* V3-11 14/11/2012 Overhalled RTC Code. A bug in the MicroChip RTC chip MCP79410 causes the RTC chip to corrupt the
* time if accessed continuously. To combat this, the first read of the RTC actually accesses the RTC, but
* subsequent acceses, within 0.5 seconds, access the previosuly read values. This means that if you continuously
* access the RTC chip, you will only get a fresh reading every 0.5 seconds. Many bug fixes were also done to the
* RTC code.
*
* V4-00 4/3/2013 Changed to V4 for 64K splat memory. Included the latest SPLat interpreter and MODBUS files.
*
* V4-10 5/3/2014 Minor fix to oblcd_fidspW accuracy. This version not released.
*
* V4-11 5/3/2014 Fixed a bug in the string comms module where the COM_flags instruction had not been fully implemented.
*
* V4-12 11/7/2014 Added BlinkM, InputM and InputMK instruction. Reports dialect 29.
2. Download SPLat reFlash
Download then run SPLat reFlash on your PC. This tool will upload the firmware to your SPLat controller. You will need a serial port or USB to serial adaptor and may also need a PC232 programming cable.
Windows 8.x Users
The first time you run reFlash, you will need to do so as the Administrator, otherwise you will see an error about HIRESTIMER.OCX not being registered. After you’ve done this once, you can run it normally in future.
If you’re not sure what you want, give us a call: +61 3 9773 5082